Cover image for Fault Tolerant Storage Multipathing and Clustering Solutions for Open Systems for the IBM ESS.
Fault Tolerant Storage Multipathing and Clustering Solutions for Open Systems for the IBM ESS.
Title:
Fault Tolerant Storage Multipathing and Clustering Solutions for Open Systems for the IBM ESS.
Author:
Redbooks, IBM.
Personal Author:
Physical Description:
1 online resource (260 pages)
Contents:
Front cover -- Contents -- Figures -- Tables -- Preface -- The team that wrote this redbook -- Special notice -- IBM trademarks -- Comments welcome -- Chapter 1. Introduction -- 1.1 Introduction to the IBM Enterprise Storage System -- 1.1.1 The Seascape architecture -- 1.1.2 Enterprise Storage System overview -- 1.1.3 ESS Copy Services components -- FlashCopy -- Peer-to-Peer Remote Copy (PPRC) -- 1.2 Introduction to high availability concepts -- 1.2.1 Multipathing -- What is multipathing? -- When is it used? -- Static and dynamic load balancing -- Why you need multipathing software -- 1.2.2 Mirroring -- What is mirroring? -- Software mirroring -- Hardware mirroring -- Why is it used? -- 1.2.3 Multipathing versus mirroring -- 1.2.4 Clustering -- What is it? -- Why is it used? -- Chapter 2. Basic concepts of ESS with multipathing and clustering -- 2.1 Concepts of high availability -- 2.1.1 What is high availability? -- Downtime issues -- 2.1.2 Single system availability -- 2.1.3 Increasing availability by clustering -- Clustering concept basics -- 2.2 How disks are seen on ESS -- 2.2.1 Overview -- 2.2.2 SCSI -- Targets and LUNs -- SCSI host system limitations -- 2.2.3 Fibre Channel -- Targets and LUNs -- Fibre Channel access modes -- 2.2.4 Fibre Channel Storage Area Networks (SANs) -- 2.3 Managing the number of paths to a LUN -- 2.3.1 How many paths are seen -- SCSI connection -- Fibre Channel connections -- 2.3.2 How to reduce paths -- Reduce by ESS configuration -- Reduce by zoning -- Reduce by adapter profiles -- Reduce by SAN management software -- 2.3.3 Paths over inter switch links -- Chapter 3. Multipathing software -- 3.1 IBM Subsystem Device Driver -- 3.1.1 Path algorithms -- Single-path mode -- Multiple-path mode -- 3.1.2 How many paths to use with SDD -- 3.1.3 Usage of datapath command -- Usage of datapath query adapter command.

Usage of datapath query adaptstats command -- Usage of datapath query device command -- Usage of datapath query devstats command -- Usage of datapath set adapter command -- Usage of datapath set device command -- 3.2 HP-UX LVM built-in support for Physical Volume Links -- 3.3 Veritas VxVM built-in Dynamic MultiPathing software (DMP) -- 3.3.1 Supported disk arrays -- 3.3.2 Path failover and load balancing -- Chapter 4. Clustering concepts -- 4.1 What is a cluster? -- 4.2 The benefits of clustering -- 4.2.1 Why consider a cluster? -- High availability -- Scalability -- Performance -- Price/performance -- Manageability -- Administrative clustering -- 4.2.2 What is high availability? -- 4.2.3 Server consolidation -- Logical consolidation -- Physical consolidation -- Re-centralization -- 4.3 Types of clusters -- 4.3.1 Software for clusters -- 4.3.2 Hardware for clusters -- Shared disk -- Shared nothing -- 4.3.3 Active and passive servers -- Active / active -- Active / passive -- Hybrid -- 4.4 IBM cluster strategy -- 4.5 Linux clustering -- High performance computing or scientific computing -- Load balancing or scalability -- High availability and failover -- 4.5.1 Implementing Linux clustering -- 4.5.2 Failover service -- 4.5.3 Load balancing -- Direct routing -- Network Address Translation -- Tunneling -- 4.5.4 Supported services -- 4.5.5 Sharing the data between nodes -- rsync -- Network File System (NFS) -- Global File System (GFS) -- Intermezzo -- Back-end database -- 4.5.6 Putting it all together -- 4.6 RS/6000 Cluster Technology (RSCT) overview -- 4.6.1 Topology Services (TS) -- TS overview -- 4.6.2 Group Services (GS) -- GS overview -- 4.6.3 Event Management (EM) -- EM overview -- Chapter 5. SDD installation and configuration on AIX -- 5.1 Pre-installation checks -- 5.2 Hardware and software requirements -- 5.2.1 SCSI requirements.

5.2.2 Fibre Channel requirements -- 5.2.3 Non supported environments -- 5.3 Installing and configuring Fibre Channel device drivers -- 5.3.1 Installing Fibre Channel device drivers -- Verifying the installation -- 5.3.2 Gigabit Fibre Channel Adapter for PCI bus FC 6227 (type 4-S) features -- 5.3.3 2-Gigabit Fibre Channel Adapter for PCI bus FC 6228 (type 4-W) features -- 5.3.4 Problem determination -- Complexity of the Fibre Channel Environment -- Nature of Fibre Channel environment problems -- Upgrading the Fibre Channel adapter firmware -- 5.4 Installing and configuring the IBM Subsystem Device Driver -- 5.4.1 Installing the IBM Subsystem Device Driver -- Verifying the SDD Installation -- Major files installed with SDD software -- 5.4.2 Configuring the Subsystem Device Driver -- Preparing to configure the Subsystem Device Driver -- Configuring the Subsystem Device Driver -- Verifying the SDD configuration -- Changing the path-selection policy -- Adding paths to SDD devices which belongs to a volume group -- 5.4.3 Unconfiguring the Subsystem Device Driver devices -- 5.4.4 Removing the Subsystem Device Driver -- 5.5 Using IBM SDD on AIX host -- 5.5.1 Providing load-balancing and failover protection -- Displaying the ESS vpath device configuration -- Configuring a volume group for failover protection -- Importing a volume group with SDD -- Exporting a volume group with SDD -- How failover protection can be lost -- Recovering from mixed volume groups -- Extending an existing SDD volume group -- Backing-up all files belonging to a SDD volume group -- Restoring all files belonging to a SDD volume group -- SDD-specific SMIT panels -- 5.5.2 Using ESS devices directly -- 5.5.3 Using ESS devices through AIX LVM -- 5.5.4 Migrating non-SDD volume group to ESS SDD multipath volume group -- 5.5.5 SDD utility programs -- Usage of datapath command.

5.5.6 SDD error log messages -- 5.6 How to use HACMP with SDD -- 5.6.1 Understanding the SDD support for HACMP/6000 -- 5.6.2 What's new in SDD for HACMP/6000 -- 5.6.3 Special requirements for HACMP/6000 -- How to recover paths that are lost during HACMP/6000 node failover -- 5.6.4 Models of the ESS supported in HACMP/6000 environment -- 5.7 Upgrading SDD for AIX 4.2.1, AIX 4.3.2 and AIX 4.3.3 -- 5.7.1 Upgrading to SDD 1.3.0.x through a non-disruptive installation -- 5.7.2 Upgrading to SDD 1.3.0.x through a disruptive installation -- 5.8 Using concurrent download of licensed internal code -- Chapter 6. DMP installation and configuration on Sun servers -- 6.1 Concepts of multipathing and clustering on Sun platform -- 6.2 Hardware and software requirements -- 6.2.1 Hardware -- 6.2.2 Software -- 6.2.3 Non supported environments -- 6.3 Preparing the environment -- 6.3.1 Installing the operating system -- 6.3.2 Configuring all HBAs -- sd_max_throttle -- sd_io_time -- set maxphys -- 6.3.3 Emulex -- automap=1 -- -- fcp-on=1 -- -- lun-queue-depth -- network-on=0 -- -- topology=2 -- -- zone-rscn=1 -- -- 6.3.4 JNI -- fca_nport -- public_loop = 0 -- -- ip_disable = 1 -- -- scsi_probe_delay = 5000 -- -- failover = 60 -- -- 6.3.5 Setting up the ESS -- 6.3.6 Attaching an ESS to a Sun Solaris Enterprise Servers -- 6.4 Using the SDD -- 6.4.1 When to use SDD -- 6.4.2 Installing the Subsystem Device Driver -- Post-installation -- 6.4.3 Uninstalling the Subsystem Device Driver -- 6.5 Installing and configuring Veritas Volume Manager -- 6.5.1 Creating a filesystem under Veritas -- 6.5.2 Sun Veritas and ESS logical volumes -- 6.5.3 ESS identification under Veritas -- 6.6 Installing and configuring cluster software -- Chapter 7. SDD installation and configuration on HP-UX servers -- 7.1 Concepts of multipathing and clustering on HP-UX platform.

7.2 Hardware and software requirements -- 7.2.1 Hardware -- 7.2.2 Software -- 7.2.3 Non supported environments -- 7.3 Preparing the environment -- 7.3.1 Pre-installation planning -- 7.3.2 Installing the operating system -- 7.3.3 Installing and confirming HP-UX installation patches -- 7.3.4 Confirming correct installation of the host bus adapter -- 7.3.5 Setting up the ESS -- 7.3.6 Attaching an ESS to a Hewlett Packard 9000 -- 7.3.7 Confirming storage connectivity -- Switched fabric -- Fibre Channel Arbitrated Loop -- 7.3.8 Tuning recommendations -- 7.3.9 Installing and configuring cluster software -- 7.4 Installing and uninstalling the SDD -- 7.4.1 What is PV-Link? -- 7.4.2 How to use PV-Links -- 7.4.3 PV-Link versus SDD -- 7.4.4 Installing SDD -- Verifying the SDD Installation and preparing the vpaths -- Creating Volume Groups using the SDD -- Configuring the Volume Groups using the SDD -- 7.4.5 Uninstalling SDD -- Verifying the SDD uninstallation -- Chapter 8. Installing Fibre Channel and configuring multipathing on SGI IRIX 6.5 -- 8.1 Supported configurations -- Direct connection -- Switched fabric -- 8.2 Installation of Fibre Channel on SGI IRIX 6.5 -- 8.2.1 Confirming IRIX installation -- 8.2.2 Confirming QLA2200F installation -- 8.2.3 Setting up ESS -- Adding or modifying SGI connections -- Configuring host adapter ports -- Adding and assigning volumes -- 8.2.4 Installing optical cable -- Switched fabric -- Fibre Channel Arbitrated Loop -- 8.2.5 Confirming switch connectivity -- Switched fabric only -- Zoning -- 8.2.6 Confirming storage connectivity -- Switched fabric LUN -- Fibre Channel Arbitrated Loop -- 8.3 Configuring host path failover -- 8.3.1 General considerations -- 8.3.2 Switched fabric -- 8.3.3 Fibre Channel Arbitrated Loop -- 8.3.4 Manually switch IO between the primary and alternate path -- 8.4 Working with ESS volumes.

8.4.1 Configuring storage.
Local Note:
Electronic reproduction. Ann Arbor, Michigan : ProQuest Ebook Central, 2017. Available via World Wide Web. Access may be limited to ProQuest Ebook Central affiliated libraries.
Electronic Access:
Click to View