Use of amine-and mercapto-modified silica as soild phase extraction sorbent for speciation of inorganic selenium prior to determination by atomic spectrometric techniques
tarafından
 
Dönertaş, Esen.

Başlık
Use of amine-and mercapto-modified silica as soild phase extraction sorbent for speciation of inorganic selenium prior to determination by atomic spectrometric techniques

Yazar
Dönertaş, Esen.

Yazar Ek Girişi
Dönertaş, Esen.

Yayın Bilgileri
[s.l.]: [s.n.], 2010.

Fiziksel Tanımlama
ix, 49 leaves.: ill. + 1 computer laser optical disc.

Özet
Silica-based sorbents containing amino-, mercapto-, and both functional groups (bifunctional) were prepared and used for the sorption of inorganic Se(IV) and Se(VI) species from waters prior to their determination by atomic spectrometric techniques, namely, inductively coupled plasma mass spectrometry (ICP-MS) and hydride generation atomic absorption spectrometry (HGAAS). The presence of the functional groups on the surface of the silica was demonstrated by using several characterization techniques such as scanning electron microscopy (SEM), solid-state NMR spectroscopy, thermo gravimetric analysis (TGA), elemental analysis and Brunauer-Emmett-Teller (BET) surface area analysis. Amine-modified silica was found to be selective towards Se(VI) at pHs 2.0 and 3.0 whereas mercapto-modified silica retains Se(IV) over a wide range from acidic regions to pH 4.0. Bifunctional silica, on the other hand, possesses the good features of the two sorbents; it can be used in the separate sorption of Se(IV) or of both Se(IV) and Se(VI) species. Acidic pHs (<1.0) are convenient for the sorption of Se(IV) alone where no sorption is observed for Se(VI). Alternatively, pH can be adjusted to 2.0 or 3.0 and Se(IV) and Se(VI) can be retained simultaneously. Desorption of selenium species from the sorbents was realized with two different eluents; 0.2% (m/v) KIO3 in 1 M HCl was used for Se(IV) and 2.0 M HCl for Se(VI). The efficiency of the proposed sorbents was demonstrated through spike recovery tests carried out with bottled drinking and tap water samples and the percentage recoveries were found to change between 82.2 ± 7.1 and 109.4 ± 3.6 for Se(IV). For Se(VI), mechanically mixed amino- and mercapto-modified (MIX) silicas in (1:1) ratio has shown the best performance with percentage recoveries of 87.1 ± 3.6 and 74.5 ± 6.6 for the spiked bottled drinking and tap water samples, respectively.

Konu Başlığı
Selenium.
 
Silica.
 
Selenium -- Spectra.
 
Atomic spectroscopy -- Technique.

Yazar Ek Girişi
Eroğlu, Ahmet E.

Tüzel Kişi Ek Girişi
İzmir Institute of Technology. Chemical Engineering.

Tek Biçim Eser Adı
Thesis (Master)--İzmir Institute of Technology: Chemical Engineering.
 
İzmir Institute of Technology: Chemical Engineering--Thesis (Master).

Elektronik Erişim
Access to Electronic Version.


LibraryMateryal TürüDemirbaş NumarasıYer NumarasıDurumu/İade Tarihi
IYTE LibraryTezT000195QD181.S5 D68 2010Tez Koleksiyonu