Laser induced breakdown spectroscopic analysis of metal aerosols generated by pneumatic nebuliztion of aqueous solutions
tarafından
 
Ateş Arıca, Dilek.

Başlık
Laser induced breakdown spectroscopic analysis of metal aerosols generated by pneumatic nebuliztion of aqueous solutions

Yazar
Ateş Arıca, Dilek.

Yazar Ek Girişi
Ateş Arıca, Dilek.

Yayın Bilgileri
[s.l.]: [s.n.], 2010.

Fiziksel Tanımlama
x, 55 leaves.: ill. + 1 computer laser optical disc.

Özet
Laser Induced Breakdown Spectroscopy, LIBS, is an analytical technique used to determine the elemental composition of samples in all forms. In this study, an experimental LIBS system has been designed and constructed for the analysis of metal aerosol particles that are generated by a pneumatic nebulizer. This research provides a basis and preliminary data for the construction of a portable LIBS system to analyze metals in aqueous environments.The aerosol particles generated from the pneumatic nebulizer travel through a sample introduction unit to reach the sample cell in which they interact with the laser beam. The source of light is a Nd:YAG laser at 532 nm, 10 Hz. When the laser beam is focused inside the sample cell, plasma is generated, and the emission containing the spectral information about the sample being analyzed is focused onto the spectrograph and detected by a gated detector. The optimum optical and experimental parameters were systematically investigated.The aqueous analyte solutions were prepared from their salts before introduced into the system. In this work, laser-induced breakdown spectroscopic emissions of Na, Ca, Mg and K aerosols were studied. In single shot mode, the minimum detectable aqueous concentrations were found as 250 ppb, 500 ppb, 400 ppb and 10 mg/L respectively. For 10 shot accumulated analyses in repetitive mode, based on 3. criterion, the detection limit (LOD) was determined as 1 mg/L, 0.6 mg/L, 1.5 mg/L and 16.3 mg/L respectively. The efficiency of the drying unit has been evaluated by particle size measurements. It has been shown that the Na aerosols with particle size of 4.3 .m decreases to 0.5 .m after passing through the membrane dryer unit.

Konu Başlığı
Aerosols -- Analysis.
 
Laser-induced breakdown spectroscopy.
 
Solution(chemistry)

Yazar Ek Girişi
Yalçın, Şerife.

Tüzel Kişi Ek Girişi
İzmir Institute of Technology. Chemistry.

Tek Biçim Eser Adı
Thesis (Master)--İzmir Institute of Technology: Chemistry.
 
İzmir Institute of Technology: Chemistry--Thesis (Master).

Elektronik Erişim
Access to Electronic Version.


LibraryMateryal TürüDemirbaş NumarasıYer NumarasıDurumu/İade Tarihi
IYTE LibraryTezT000206QD549 .A86 2010Tez Koleksiyonu