Development of inductively coupled plasma spectroscopic methods for the determination of metals in beluga (delphinapterus leucas) and pygmy sperm (kogia breviceps) whale liver samples
tarafından
 
Parlayan, Filiz.

Başlık
Development of inductively coupled plasma spectroscopic methods for the determination of metals in beluga (delphinapterus leucas) and pygmy sperm (kogia breviceps) whale liver samples

Yazar
Parlayan, Filiz.

Yazar Ek Girişi
Parlayan, Filiz.

Yayın Bilgileri
[s.l.]: [s.n.], 2005

Fiziksel Tanımlama
xiii, 137 leaves.: ill.+ 1 computer laser optical disc

Genel Not
Keywords: ICP-OES, Chemometrics methods, internal standardization, matrix effects.

Özet
Inductively couple plasma optical emission spectrometry (ICP-OES) is widely used to monitor elements in biological samples from marine organisms for ecological evaluations. Matrix effects (particularly those related to acid and salt type and concentrations) can present a barrier to the applicability of this instrumental method. To have a better understanding of these effects and to choose a suitable internal standard to correct for the signal variations, a procedure based on Principal Component Analysis (PCA) of the data from an axial-mode ICP-OES instrument with sequential detection was performed. Different from other published studies, it was found that ionic lines were more affected by matrix changes. Elements with high ionization energies and energy sums such as Cd and Zn showed a significant change for signal intensities and calculated concentrations due to the presence of acid, salt, and multielement matrix effects. It was observed that acid has a higher influence on the analyte signal as compared to the "salt-only" case. Furthermore, when several interfering elements were present in the sample, the matrix effect was either enhanced or reduced when compared with a solution containing only a single interfering element. Applicability of the proposed technique for the analysis of whale liver homogenate NIST certified material was investigated. The values of the corrected concentrations were in good agreement with the certified values, confirming the capabilities of the selected internal standards for compensation of matrix effects.

Konu Başlığı
Inductively coupled plasma spectrometry
 
Plasma spectroscopy
 
Matrix effect

Yazar Ek Girişi
Eanes, Ritchie

Tüzel Kişi Ek Girişi
İzmir Institute of Technology. Chemistry

Tek Biçim Eser Adı
Thesis (Master)--İzmir Institute of Technology:Chemistry
 
İzmir Institute of Technology:Chemistry--Thesis (Master).

Elektronik Erişim
Access to Electronic Version.


LibraryMateryal TürüDemirbaş NumarasıYer NumarasıDurumu/İade Tarihi
IYTE LibraryTezT000399QD96.I47.P22 2005 C.1Tez Koleksiyonu