The development of chemometric methods based on molecular spectroscopy for the standardization of production processes and product traceability of personal care and cleaning products
tarafından
 
Çiftçi İlmek, Berfu, author.

Başlık
The development of chemometric methods based on molecular spectroscopy for the standardization of production processes and product traceability of personal care and cleaning products

Yazar
Çiftçi İlmek, Berfu, author.

Yazar Ek Girişi
Çiftçi İlmek, Berfu, author.

Fiziksel Tanımlama
x, 55 leaves: illustrarions, charts;+ 1 computer laser optical disc.

Özet
Personal care and cleaning products are the main consumer goods. Changes in our heath caused by all of the chemicals that we exposed to everyday if these products are not produced according to the regulations and determined formulations. Because of this reason, quality control of the product formulation quantitatively is very important. There are some analytical methods for the determination of anion active matter, nonionic matter and total active matter in the product mixture. However, these techniques are expensive and do not give accurate results. The purpose of this thesis principally based on development of rapid, accurate and practical infrared spectroscopic technique based on multivariate chemometrics data analysis methods for the standardization of production processes and product traceability of personal care and cleaning products. In this thesis, two different products are studied which are namely liquid soap and shower gel. Fourier Transform Infrared spectroscopy coupled with Attenuated Total Reflectance accessory based chemometrics multivariate calibration models were developed for the quantitative determination of liquid soap and shower gel compounds. Genetic Inverse Least Squares was used as the chemometrics method for the development of multivariate calibration models in the quantitative determination of liquid soap and shower gel compositions. Standard error of cross validation and standard error of prediction values for content of the liquid soap samples were found 0.26% and 0.21 % (w/w %), respectively. Standard error of cross validation and standard error of prediction values for content of the shower gel samples were found 0.27 % and 0.30 % (w/w %), respectively.

Konu Başlığı
Infrared spectroscopy.
 
Fourier transform infrared spectroscopy.
 
Cleaning compounds.
 
Hygiene products.
 
Soap.

Yazar Ek Girişi
Özdemir, Durmuş

Tüzel Kişi Ek Girişi
İzmir Institute of Technology. Chemistry.

Tek Biçim Eser Adı
Thesis (Master)--İzmir Institute of Technology:Chemistry.
 
İzmir Institute of Technology:Chemistry--Thesis (Master).

Elektronik Erişim
Access to Electronic Versiyon.


LibraryMateryal TürüDemirbaş NumarasıYer NumarasıDurumu/İade Tarihi
IYTE LibraryTezT001911QD96.I5 C56 2019Tez Koleksiyonu