Energy efficient retrofitting of historical buildings: A case study on the building of Basmane semt merkezi-İzmir için kapak resmi
Energy efficient retrofitting of historical buildings: A case study on the building of Basmane semt merkezi-İzmir
Başlık:
Energy efficient retrofitting of historical buildings: A case study on the building of Basmane semt merkezi-İzmir
Yazar:
Şahin, Cem Doğan, author.
Yazar Ek Girişi:
Fiziksel Tanımlama:
xii, 85 leaves: color illustraltions.+ 1 computer laser optical disc.
Özet:
Buildings account for 40% of total energy consumption in the European Union yet at the same time it is foreseen that they have a considerable energy saving potentials. Along with the issued energy efficiency related laws and regulations, energy efficient retrofitting applications of the existing buildings are getting increased and the new buildings are built considering the energy efficiency issues. At this point, historical buildings should be treated different than contemporary ones when energy efficient improvements matter. Therefore the specifications adding value to the historical buildings require attention and well-preservation while saving energy. The purpose of this study is to denote how the energy efficient retrofitting in historical buildings should be managed in a transdisciplinary way with a case study conducted on a historical building, Basmane Semt Merkezi-İzmir. A detailed building energy simulation tool, DesignBuilder, was used to determine the impacts of the energy efficient retrofits. The actual energy consumption of the case building was calculated obtaining the utility bills regarding electricity and heating fuel consumption. Building energy simulation tool was calibrated by comparing of the measured and simulated indoor air temperatures and total energy consumptions. The inappropriate retrofits, which contradict to the heritage and cultural values, were eliminated with an interdisciplinary approach. Later appropriates retrofits were gathered into three packages to evaluate their effects on the energy consumption. The results show that energy saving up to 41% can be obtained without damaging the heritage values. Besides, the results of combined and aggregated effects of single retrofits show considerable alterations that might cause errors in economical calculations.
Yazar Ek Girişi:
Tek Biçim Eser Adı:
Thesis (Master)--İzmir Institute of Technology:Energy Engineering.

İzmir Institute of Technology: Energy Engineering--Thesis (Master)..
Elektronik Erişim:
Access to Electronic Versiyon.
Ayırtma: Copies: