The effect of restoration interventions on the indoor climate of historic buildings: case study of Tire Necip Paşa Library, İzmir, Turkey için kapak resmi
The effect of restoration interventions on the indoor climate of historic buildings: case study of Tire Necip Paşa Library, İzmir, Turkey
Başlık:
The effect of restoration interventions on the indoor climate of historic buildings: case study of Tire Necip Paşa Library, İzmir, Turkey
Yazar:
Çağırgan, Umut, author.
Yazar Ek Girişi:
Fiziksel Tanımlama:
xiii, 101 leaves: color illustrations, charts;+ 1 computer laser optical disc.
Özet:
Libraries are collections of recorded information which can host cultural heritage values that must be protected against mechanical, chemical and biological degradation. To prevent degradations, libraries require stable indoor climates with minimal temperature and relative humidity fluctuations and low concentrations of indoor air pollutants. Aim of the thesis is to investigate if installing a HVAC system is effective in improving the indoor climate of a historic library as a long-term preventive conservation method on the preservation of paper-based collections. Tire Necip Paşa Library in İzmir was selected as the case building which underwent restoration and a HVAC system integration in 2015. Library’s indoor climate was investigated before 2015 which allowed the comparison of pre- and post-restoration periods. Within the scope of this thesis, library was monitored at five locations between 2019-2021. 2019-2020 monitoring results were compared to pre-restoration monitoring results in terms of degradation risks and ASHRAE Chapter 23 control classes. Pre- and post-restoration indoor climates satisfied A1 and AA control classes, respectively. While there were mechanical and chemical degradation risks before restoration, no risk was observed post-restoration. There was no biological degradation risk during either periods. Additionally air pollutants were sampled during summer and winter of 2020-2021 which showed high SO2 and NO2 concentrations. Lastly the BES model of library was prepared and calibrated to investigate if existing HVAC system will continue to provide a stable indoor climate on future. The results of 2050 and 2080 simulations showed that HVAC system will struggle to provide a stable indoor climate.
Tek Biçim Eser Adı:
Thesis (Master)--İzmir Institute of Technology:Architecture

İzmir Institute of Technology: Architecture--Thesis (Master).
Elektronik Erişim:
Access to Electronic Versiyon.
Ayırtma: Copies: